♦ Context Plus XFP502E/X/CON
♦ Third-party certificated to EN54 parts 2 and 4 by the LPCB.
♦ Full compatibility
♦ InterConnect Up To Eight XFP Main Panels
♦ Four XFP Repeater Panels Per Main Two Wire RS485 Network.
♦ Two Independently Programmable Conventional Sounder Circuits.
♦ Two Programmable Inputs.
| BRAND | Context Plus |
| Model | XFP502E/X/CON |
| Main supply | 230V a.± 10% 50/60Hz. Max current 680mA |
| Internal power supply | 27V d.c Nominal |
| Total output current limited to | 3A @ 230 V a.c. |
| Supply and battery charger monitored for failure | Yes |
| Batteries monitored for disconnection and failure | yes |
| Batteries protected against deep discharge | yes |
| Max. battery size and type | 7.0 Ahr VRLA |
| Specified batteries for LPCB approved systems | 2 x Yuasa NP7-12 |
| Quiescent current drain (1 loop unloaded) | < 80mA |
| Quiescent current drain (2 loop unloaded) | <100mA |
| Earth fault monitoring | Yes (any conductor) |
| Temperature compensated charging | Yes |
| Number of loop drivers | (XFP501/CON) 2 (XFP502/CON |
| Line monitored for open and short circuit faults | Yes |
| Onboard loop isolators with LED indication when active | Yes |
| Auto-polling from each loop en | Yes |
| Max. loop output current | 500mA (Voltage: 25V min, 34V max) |
| Max. number of addressable devices per loop | 126 |
| Number of programmable sounder groups | 16 |
| Number of programmable output sets | 16 |
| Number of programmable circuits | 2 |
| End of line resistor value | Yes |
| End of line resistor value | 6800 Ω 5% Tol. 0.25 W |
| Line monitored for open and short circuit faults | Yes |
| Outputs fused at | 400mA |
| Max. number of sounders @ 20mA | 80 |
| Type | Relay voltage free single pole changeover |
| Max switching current | 1A |
| Max switching voltage | 30 V d.c |
| Fault | Active when no faults are present |
| ‘24V’ Aux Power Output | 19.5V min, 28V max. Max current 100mA. Protected by resettable overload circuit |
| Input 1 | Connectto 0V to trigger. Max input voltage 27V d.c. (non-latching). Programmable from cause and effect. |
| Input 2 | Connectto 0V to trigger. Max input voltage 27V d.c (non-latching). Programmable from cause and effect. |
| Mains Fuse | 1A HRC Ceramic 20mm |
| Battery Fuse – limits the current drawn from the battery | 3.15A F 20mm |
| Control buttons | Silence, Reset, Resound, Investigate; More Information; Menu |
| Event scrolling and menu access buttons | Up (1); Down (2); Accept (3); Abort (4) |
| Liquid Crystal Display | Two lines x 40 characters, backlit |
| Number of Zonal LED indicators | 32 |
| Approx. dimensions of back box (W x H x D | 410 x 250 x 80mm (metal) |
| Approx. dimensions of lid (W x H x D) | 439 x 274 x 7mm (metal) |
| Approx. weight (without batteries) | 4.5kg |
| Type of cable | Fire resistant screened cable, minimum size 1mm2 |
| Max. cable length per loop | 1km |
| Connector blocks | Plug-on type, largest acceptable conductor size 1.5mm2 |
| Max. allowable loop impedance (each conductor | 20Ω |
| Max. cable capacitance | .27µF |
| Connection | Via AFP711 network driver card fitted at main panel |
| Temperature range | -5 to +40oC |
| Maximum relative humidity | 95% |
| Warranty | 12 Months |
| Price | ৳ 0.00 |
| Brand | ZKTeco |
| Product Model | XFP502E/X/XFP |
| Status | Out Of Stock |
| Hotline | 01711-461346, 01711-766062, 01711-126895 |
The latest price of Context Plus XFP502E/X/CON XFP Networkable Two Loop 32 Zone Addressable Panel in Bangladesh is ৳ 0.00. You can buy the Context Plus XFP502E/X/CON XFP Networkable Two Loop 32 Zone Addressable Panel at best price from our website or visit any of our showrooms.
You can buy Context Plus XFP502E/X/CON XFP Networkable Two Loop 32 Zone Addressable Panel from our online shop or in-person at our branch Uttara & Shantinagar