Toa VX-3016F Voice Evacuation Frame 16SS

Price : To be announced Regular Price : ৳ 0 Status : Pre Order Code : VX-3016F Brand : TOA

Key Features

  • Model: VX-3016F
  • Power Source : 20 - 33 V DC, removable terminal block (4 pins)
  • Operating Humidity : 90 %RH or less (no condensation)
  • Dimensions : 483 (W) × 132.6 (H) × 345 (D) mm (19.02 × 5.22" × 13.58")"
  • Weight: 8.1 kg (17.86 lb)

View More Info
প্রযুক্তি পণ্যের অস্থিতিশীল বাজার পরিস্থিতির কারণে যেকোন সময় মূল্য পরিবর্তন হতে পারে। হেল্পলাইন নাম্বারে কল দিয়ে পণ্যের স্টক ও ডেলিভারি সম্পর্কে জেনে নেওয়ার অনুরোধ রইলো

Specification

Description

Toa VX-3016F Voice Evacuation Frame 16SS

The VX-3016F is a device designed to control the Voice evacuation announcements of TOA's VX-3000 Series rack-mount type voice evacuation system which is compliant with the European Standard EN54 for fire alarm systems. It has audio input terminals and can output the amplified audio signals to the speaker lines when the optional power amplifier modules are mounted.It is possible to make an Emergency Warning Broadcast assigned a higher priority than the Emergency broadcast. Two patterns of the Emergency broadcast can be activated simultaneously.Compatible with network, the system can be configured in distributed arrangement.Features include the following functions: Digital signal processing function that enables appropriate acoustic adjustment adjustment for individual input sound sources and output amplifiers, Feedback suppressor function that automatically suppresses acoustic feedback when it occurs, VOX function that allows start/stop control of broadcast by way of an audio trigger, and ANC function that enables an ambient noise control. (The ANC function distinguishes between the unit's output sound and the ambient noise. The unit's output sound is not detected as noise.) Indicators that show such statuses as fault status and power amplifier signal status are provided.It has 16 speaker output channels. The number of mountable amplifier modules is up to 2 when used as zone amplifiers or a total of 2 when one is used as standby amplifier and the other as zone amplifier. When one module for zone amplifier use is mounted, the VX-3016F can be used as 1-bus/16-zone output speaker selector. When 2 modules for zone amplifier use are mounted, it can be used as 2-channel 1-bus/8-zone output speaker selector. Zones can be expanded by connecting the unit having amplifier module(s) and the one having no amplifier module. As the VX-3016F is equipped with Standby amplifier input/output terminal, the standby amplifier, when mounted, can be shared among VX-3000F units.

 

(*1) TOA's unique technology which makes it possible to transmit high-quality audio signals in real time over an IP network
(*2) 0 dB = 1 V
(*3) Module: Digital Power Amplifier module, Line Output module

 

Power Source 20 - 33 V DC, removable terminal block (4 pins)
Power Consumption 29 W (frame only) at 33 V DC input, 95 W (RS Link: 2 A output) at 33 V DC input
Indicators POWER (green) …1, RUN (green) …1, EMERGENCY (red) …1, CPU OFF (red) …1, LAN A (green) …1, LAN B (green) …1, RS LINK A (green) …1, RS LINK B (green) …1
FAULT STATUS (yellow)
GENERAL …1, UNIT …1, NETWORK …1, EMG MIC …1, FUSE …1, POWER …1, CPU …1, ZONE …16
AMPLIFIER
PEAK (red) …2, SIGNAL (green) …2, OPERATE (green) …2, POWER (green) …2
Operation Fault Control Switch …2 (ACK/RESET)
Test Switch …1 (LAMP TEST)
Setting Switch: ID NUMBER, RESET, IMPEDANCE, Setting (internal front panel)
LAN A, B Number of Connectors: 2 (LAN A, LAN B)
Network I/F: 100BASE-TX
Network Protocol: TCP, UDP, ARP, ICMP, RTP, IGMP, FTP, HTTP
Spanning tree Protocol: RSTP
Audio Transmission System: TOA Packet Audio (*1)
Audio Encoding Method: PCM
Audio Sampling Frequency: 48 kHz
Audio Quantifying Bit Number: 16 bits
Connection Device: VX-3004F, VX-3008F, Other VX-3016F, NX-300, VX-3000PM, VX-3000CT, Switching HUB
Connector: RJ45 connector
Connection Cable: Category 5 twisted pair cable (CAT5)
Number of Stages of Cascade connection: UP to 7
Maximum Cable Distance: 100 m (328.08 ft)
RS Link A, B Number of Connectors: 2 (RS LINK A, RS LINK B)
Audio input level: 0 dB (*2)
Power feed: Max. 1 A per connector
Connector: RJ45 connector
Connection Cable: Shielded Category 5 twisted pair cable (CAT5-STP)
Maximum Cable Distance: 1200 m (3937.01 ft)
DS Link Connection Device: DS LINK of Power supply units
Connector: RJ45 connector
Connection Cable: Shielded Category 5 twisted pair cable (CAT5-STP)
Maximum Cable Distance: 5 m (16.4 ft)
Analog Link Number of Connectors: 1 input, 1 output
Connection Device: VX-3004F, VX-3008F, Other VX-3016F
Connector: RJ45 connector
Connection Cable: Shielded Category 5 twisted pair cable (CAT5-STP)
Maximum Cable Distance: 800 m (2624.67 ft)
Control Input 1, 2 16 inputs, no-voltage make contact input, open voltage: 24 V DC, short-circuit current: 2 mA
Fault Detection System: Short circuit, Open circuit, Method: Voltage detect
Connector: RJ45 connector
Connection Cable: Shielded Category 5 twisted pair cable (CAT5-STP)
Emergency Control IN Input 2: Isolated voltage input, -24 to +24 V
Connector: RJ45 connector
Connection Cable: Category 5 twisted pair cable (CAT5)
VOX Function Threshold: -60 to 0 dB (1 dB steps)
Hysteresis: 0 to +10 dB, Hold time: 10 ms - 10 s
Settable for each audio input
Control Output 1, 2 General outputs : 8 with CONTROL OUTPUT 1
Exclusive outputs : 3 with CONTROL OUTPUT 2 GENERAL FAULT, CPU FAULT, CPU OFF
No-voltage make contact, electrical contact output, control current: 10 mA, withstand voltage: 28 V DC
Connector: RJ45 connector
Connection Cable: Shielded Category 5 twisted pair cable (CAT5-STP)
ATT/Control Output 16 outputs, no-voltage make contact, relay contact (NC, NO, C), control current: 2 mA to 5 A, withstand voltage: 125 V AC, 40 V DC
Connector: Removable terminal block (12 pins) …4
Audio Input 1, 2, 3, 4 4 inputs
Sensitivity:
LINE: -20 dB (*2), MIC: -60 dB (*2)
LINE/MIC/ANC Sensor (changeable with setting software)
Gain Control: volume adjustable with volume control (internal front panel)
- ∞ to 0 dB
Input Impedance: 47 kΩ, electronically-balanced
Frequency Response: 40 Hz - 20 kHz ±1 dB (at DA CONTROL LINK, 0 dB output)
Distortion: 1% or less (at DA CONTROL LINK, 0 dB output, 1 kHz)
Signal to Noise Ratio: 60 dB or more (at DA CONTROL LINK, A-weighted)
Phantom Power Supply: 24 V DC, can be set with setting software
Connector: Removable terminal block (6 pins) …2

Digital Signal Processing
Feedback Suppression Function 7 filters (auto), Settable for each audio input and RS LINK (A/B)
Equalizer/Filter 3 bands for each audio input and RS LINK (A/B), 6 bands for each amplifier output
Parametric equalizer: 20 Hz - 20 kHz, ±15 dB, Q: 0.267 - 69.249
Filtering: High-pass filter 20 Hz - 20 kHz, 6 dB/oct, 12 dB/oct
              Low-pass filter 20 Hz - 20 kHz, 6 dB/oct, 12 dB/oct
              High shelving filter 6 - 20 kHz, ±15 dB
              Low shelving filter 20 - 500 Hz, ±15 dB
              Notch filter (amplifier output only) 20 Hz - 20 kHz, Q: 8.651 - 69.249
              All-pass filter (amplifier output only) 20 Hz - 20 kHz, Q: 0.267 - 69.249
              Horn equalizer (amplifier output only) 20 kHz, 0 to +18 dB (0.5 dB steps)
Compressor Threshold: -20 to 0 dB (1 dB steps)
Ratio: 1:1, 1.1:1, 1.2:1, 1.3:1, 1.5:1, 1.7:1, 2:1, 2.3:1, 2.6:1, 3:1, 4:1, 5:1, 7:1, 8:1, 10:1, 12:1, 20:1, ∞:1
Attack time: 0.2 ms - 5 s, Release time: 10 ms - 5 s
Gain: - ∞ to +10 dB, Knee type: hard knee, middle knee, soft knee
Delay For each amplifier output, 0 - 2730 ms (0.021 ms steps)
ANC(Ambient Noise Control) Amplifier output level control, Automatic sensor input reference level measuring, Sensor input reference level fine adjustment
Maximum output signal level control: -15 to 0 dB
Minimum output signal level control: -18 to -3 dB
Sample time setting: 10 s, 20 s, 30 s, 1 min, 5 min
Gain ratio setting: (Ambient noise: Output signal level) 6:3, 5:3, 4:3, 3:3, 3:4, 3:5, 3:6
Ambient noise measuring frequency setting: 20 Hz - 20 kHz, 3 points
Speaker Line 16 channels, 2 Earth terminals
Maximum Voltage/Current: 100 Vrms, 5 Arms
Connector: Removable terminal block (17 pins) …2
Fault Detection System: Short circuit, Open circuit, Ground fault, Method: Impedance or End of line
Standby Amplifier Input/Output Input: 1, Output: 1
Maximum Voltage/Current: 100 Vrms, 5 Arms
Connector: Removable terminal block (2 pins) …2
Extension Amplifier Input/Output Input: 1, Output: 1
Maximum Voltage/Current: 100 Vrms, 5 Arms
Connector: Removable terminal block (2 pins) …2
Modules (*3) Number of Modules: 2
DA CONTROL LINK …2
DA OUTPUT LINK …2  (Used only when a Power Amplifier module is installed)
Operating Temperature -5 ℃ to +45 ℃ (23 ゜F to 113 ゜F)
Operating Humidity 90 %RH or less (no condensation)
Finish Panel: Surface-treated steel plate, black, 30 % gloss, paint
Dimensions 483 (W) × 132.6 (H) × 345 (D) mm (19.02 × 5.22" × 13.58")
Weight 8.1 kg (17.86 lb)
Accessory Rack mounting bracket (preinstalled on the unit) …2, Rack mounting screw ...4, CD (PC setting software) …1, Removable terminal plug (2 pins) …4, Removable terminal plug (4 pins) …1, Removable terminal plug (6 pins) …2, Removable terminal plug (12 pins) …4, Removable terminal plug (17 pins) …2, Ferrite clamp …2

TOA VX-3016F Price in Bangladesh

Price To be announced
Brand TOA
Product Model VX-3016F
Status Pre Order
Hotline 0185-3330346, 01711-461346, 01711-766062

Product Videos

What is the price of Toa VX-3016F Voice Evacuation Frame 16SS in Bangladesh?

The latest price of Toa VX-3016F Voice Evacuation Frame 16SS in Bangladesh is ৳ 0.00. You can buy the Toa VX-3016F Voice Evacuation Frame 16SS at best price from our website or visit any of our showrooms.


Where to buy Toa VX-3016F Voice Evacuation Frame 16SS in Bangladesh?

You can buy Toa VX-3016F Voice Evacuation Frame 16SS from our online shop or in-person at our branch Uttara & Shantinagar

Customer Questions & Answer

No questions asked yet.

Your Question (Please don`t use any links, &, (, ), ?, /, +, $, # Symbols)

Leave a review

Your email address will not be published. Required fields are marked *

Your Rating * :

WhatsApp Chat with us

Hi! How can we help you?